The cooling water systems play a vital role in large steam power plants as they
directly affect the condenser back pressure, turbine efficiency, and overall plant
heat rate. This paper presents an in-situ detailed case study of the performance of
the cooling water (CW) system in a 1070 MW ultra-supercritical coal-fired steam
power plant at three steady-state load levels, i.e., 100% (1070 MW), 75% (803
MW), and 50% (535 MW). Actual operating data obtained from the Distributed
Control System (DCS), such as condenser pressure, CW inlet/outlet temperatures,
temperature rise (ΔT), CW mass flow rate, exhaust steam flow, heat duty,
logarithmic mean temperature difference (LMTD), and total heat transfer
coefficient (U), are reviewed and compared to results from a verified steady-state
simulation model. The research results show a deviation between the measured
and simulated condenser pressure values, with a validation margin of less than
5% for the main parameters. This indicates that cooling water (CW) flow varies
under partial load conditions to avoid excessive auxiliary power consumption,
and provides quantitative insights for load-dependent optimization of cooling
water (CW) flow. The condenser pressure at 50% load is 60.6 mbar, considerably
less than the projected 73 mbar, thus affirming the existence of surplus cooling
capacity and the opportunity to decrease pump flow. These results are useful in
developing better operational strategies for increasing thermal efficiency and
decreasing specific auxiliary consumption of large-scale fossil-fuel power plants.
Keywords: Part-load performance, Cooling water flow, Steam power plant,
Surface condenser, Condenser backpressure, Thermal optimization, Simulation
validation, DCS data.